Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
c.a. 500 mPa.s at 25°C
Key result
Flash point:
ca. 92 °C
Atm. press.:
ca. 1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the target substance is 92°C by ASTM D93 method.

Description of key information

Key value for chemical safety assessment

Flash point at 101 325 Pa:
92 °C

Additional information