Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-03-01 - 2017-05-18
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Part I: Classification procedures, test methods and criteria relating to explosives of Class 1
Version / remarks:
Revision 6 (2015)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: OECD Test Guideline 113: Thermal Stability
Version / remarks:
1981
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
other: Thermal Stability via DSC
Remarks on result:
other: Due to the fact that the exothermal decomposition energy is < 500 J/g, explosive properties can be excluded.

Results

Thermal stability (DSC)

No thermal effects could be observed up to the maximum test temperature of 500 °C.

Table 1:    Results of the DSC-measurements

No.

Sample weight / mg

Onset / °C

Energy / J/g

Remark

PN13007

8.38

---

---

PN13008

11.89

---

---

Due to the fact that the test item showed no exothermal decomposition, further tests on explosive properties did not have to be performed.

Interpretation of results:
GHS criteria not met
Conclusions:
Final Results:
In the DSC-measurement no exothermic decomposition of the test item Leuco Sulfur Blue 20 occurred. Due to this result, further tests for explosive properties had not to be performed. The test item has no explosive properties according to Recommendations on the TRANSPORT OF DANGEROUS GOODS: Manual of Tests and Criteria, 6th edition, New York and Geneva, 2015: Class 1.

According to the results of the test on thermal stability, the test item is classified as following:
UN Transport Regulation: The test item does not have to be classified as explosive substance in class 1 according to the UN Transport Regulation.
GHS (CLP Regulation EC 1272/2008: Annex 1: 2.1): The test item does not have to be classified as explosive substance according to GHS or CLP Regulation EC 1272/2008 Annex 1: 2.1, respectively.
Executive summary:

Summary

In the DSC-measurement no exothermic decomposition of the test item Leuco Sulfur Blue 20 occurred. Due to this result, further tests for explosive properties had not to be performed.

The test item has no explosive properties according to Recommendations on the TRANSPORT OF DANGEROUS GOODS: Manual of Tests and Criteria, 6thedition, New York and Geneva, 2015: Class 1.

According to the results of the test on thermal stability, the test item is classified as following:

UN Transport Regulation: The test item does not have to be classified as explosive substance in class 1 according to the UN Transport Regulation.

GHS (CLP Regulation EC 1272/2008: Annex 1: 2.1): The test item does not have to be classified as explosive substance according to GHS or CLP Regulation EC 1272/2008 Annex 1: 2.1, respectively.

Description of key information

In the DSC-measurement no exothermic decomposition of the test item Leuco Sulfur Blue 20 occurred. Due to this result, further tests for explosive properties had not to be performed. The test item has no explosive properties and does not have to be classified as explosive substance in class 1 according to the UN Transport Regulation. The test item does not have to be classified as explosive substance according to GHS or CLP Regulation EC 1272/2008 Annex 1: 2.1, respectively.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification

Classification, Labelling, and Packaging Regulation (EC) No 1272/2008

The available experimental test data are reliable and suitable for classification purposes under Regulation (EC) No 1272/2008. Based on available data, the test item is not classified for explosiveness according to Regulation (EC) No 1272/2008 (CLP).