Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31Oct2017 - 09Jan2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3,7-dihydropurin-6-one;sodium
Cas Number:
45738-97-4
Molecular formula:
C5H3N4NaO
IUPAC Name:
3,7-dihydropurin-6-one;sodium
Test material form:
solid: particulate/powder
Details on test material:
- Appearance: White powder
- Purity / Composition: 98%
- Test item storage: Room temperature
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Batch No.of test material: 16K235305
- Purity: 98.0%

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
4 min
Remarks on result:
other:
Remarks:
Test item not propagate combustion along 200 mm of the pile within the 4 minutes test period (per EC A.10 guideline).

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Based on the results obtained, the test item is considered ‘not highly flammable’.
Executive summary:

In contact with the flame of the gas burner the test item glowed and turned into a black residue. White smoke was observed.  After removal of the ignition source, no propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed.  According to the guidelines, performance of the burning rate test is not required.

Based on the results obtained, the test item is considered ‘not highly flammable’.