Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-05-24 to 2017-06-01
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7100 (Viscosity)
Version / remarks:
1996
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
ISO 3104 (Petroleum products - Transparent and opaque liquids - Determination of kinematic viscosity and calculation of dynamic viscosity)
Version / remarks:
1999
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
other: CIPAC Guideline MT 22: Viscosity
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
Name: Vinylcyclohexan
CAS No.: 695-12-5
Batch No.: VCH/7/17K1
Purity: 99.8 % (GC)
Description: clear liquid
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.95
Key result
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.77

Test Results

Two test series of 2 measurements, respectively, at temperatures of 20°C and 40°C were performed. The test results of the measurements are presented in the following tables.

Results of the measurements at a temperature of 20°C:

Measure-ment
no.

Rundown-time /
s

Mean time /
s

Standard deviation /
s

Capillary constant / mm²/s²

Kinematic viscosity /
mm²/s

Remark

1

32.66

32.66

<0.1

0.028951

0.95

-

2

32.66

-

Results of the measurements at a temperature of 40°C:

Measure-ment
no.

Rundown-time /
s

Mean time /
s

Standard deviation /
s

Capillary constant / mm²/s²

Kinematic viscosity /
mm²/s

Remark

1

26.46

24.46

<0.1

0.028951

0.77

-

2

26.46

-

Conclusions:
The kinematic viscosity of the test item vinylcyclohexane was determined at temperatures of 20°C and 40°C according to OECD Test Guideline 114 (2012) Viscosity of Liquids. At 20°C and 40°C, the kinematic viscosity is 0.95 mm²/s and 0.77 mm²/s, respectively.
Executive summary:

The kinematic viscosity of the test item vinylcyclohexane was determined at temperatures of 20°C and 40°C according to OECD Test Guideline 114 (2012) Viscosity of Liquids. At 20°C and 40°C, the kinematic viscosity is 0.95 mm²/s and 0.77 mm²/s, respectively.

Description of key information

The kinematic viscosity of the test item vinylcyclohexane was determined at temperatures of 20°C and 40°C according to OECD Test Guideline 114 (2012) Viscosity of Liquids. At 20°C and 40°C, the kinematic viscosity is 0.95 mm²/s and 0.77 mm²/s, respectively.

Key value for chemical safety assessment

Viscosity:
0.77 mm²/s (static)
at the temperature of:
40 °C

Additional information