Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Type of method:
closed cup
Key result
Flash point:
> 98 °C
Atm. press.:
101.3 kPa
Conclusions:
The flash point of N-acetylcaprolactam was determined according to EU method A9 by the Pensky-Martens closed cup method and is above 98 °C at 101.3 kPa.

Description of key information

The flash point of the test substance N-acetylcaprolactam was determined according to EU method A9 by the Pensky-Martens closed cup method.

Key value for chemical safety assessment

Additional information

The flash point of N-acetylcaprolactam is above 98 °C at 101.3 kPa (Pensky-Martens method, DINEN ISO 2719).