Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
8th - 20th September, 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes
Type of method:
open cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 7683104
- Expiration date of the lot/batch: 2018-09-30
Flash point:
120.5 °C
Atm. press.:
1 013 mBar
Interpretation of results:
GHS criteria not met
Conclusions:
The test item is not a flammable liquid.
Executive summary:

The flash point was determined in accordance with EU Test Method A.9 using a Seta flash Series 7 tester. The test item showed a flash point at 120.5 °C.

Description of key information

The test item is not a flammable liquid.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
120.5 °C

Additional information

The flash point was determined in accordance with EU Test Method A.9 using a Seta flash Series 7 tester. The test item showed a flash point at 120.5°C.