Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-672-5 | CAS number: 7681-55-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Skin irritation / corrosion
Administrative data
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 19 February 2018 to 23 February 2018
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EU Method B.40 BIS (In Vitro Skin Corrosion: Human Skin Model Test)
- Deviations:
- no
- GLP compliance:
- yes
Test material
- Reference substance name:
- Sodium iodate
- EC Number:
- 231-672-5
- EC Name:
- Sodium iodate
- Cas Number:
- 7681-55-2
- Molecular formula:
- HIO3.Na
- IUPAC Name:
- sodium iodate
- Test material form:
- solid: particulate/powder
- Details on test material:
- - Appearance: white powder
- Storage conditions: at room temperature
Constituent 1
In vitro test system
- Test system:
- human skin model
- Source species:
- human
- Cell type:
- non-transformed keratinocytes
- Justification for test system used:
- Recommended test system in international guidelines
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm™ Reconstructed Human Epidermis Model kit (EPI-200)
- Tissue lot number(s): 27958
TEST FOR MTT REDUCTION
A test material may interfere with the MTT endpoint if it is coloured and/or it is able to directly reduce MTT. The cell viability measurement is affected only if the test material is present on the tissues when the MTT viability test is performed.
At least 25 mg of the test material or 50 µL Milli-Q water as a negative control were added to 1 mL MTT solution (1 mg/mL) in phosphate buffered saline. The mixture was incubated for approximately 1 hour at 37.0 ± 1.0 °C. At the end of the exposure time it was checked if a blue / purple colour change or a blue / purple precipitate was observed.
ASSESSMENT OF COLOUR INTERFERENCE WITH MTT
The test material was checked for possible colour interference before the study was started. Approximately 25 mg of the test material or 50 µL Milli-Q water as a negative control were added to 0.3 mL Milli-Q water. The mixture was incubated for approximately 1 hour at 37.0 ± 1.0 °C in the dark. At the end of the exposure time the mixture was shaken and it was checked if a blue / purple colour change was observed.
MAIN TEST
PRE-INCUBATION
The skin tissues were kept in the refrigerator the day they were received. The next day, at least 1 hour before the assay was started the tissues were transferred to 6-well plates containing 0.9 mL DMEM per well. The level of the DMEM was just beneath the tissue. The plates were incubated for approximately 1 hour at 37.0 ± 1.0 °C. The medium was replaced with fresh DMEM just before the test material was applied.
APPLICATION OF TEST MATERIAL AND CONTROLS
The test was performed on a total of 4 tissues per test material together with a negative control and positive control. Two tissues were used for a 3-minute exposure to test material and two for a 1-hour exposure. The skin was moistened with 25 µL Milli-Q water to ensure close contact of the test material to the tissue and 30.3 to 37.7 mg of the solid test material was added into the 6-well plates on top of the skin tissues.
For the negative and positive controls, 2 tissues were treated with 50 µL Milli-Q water (negative control) and 2 tissues were treated with 50 µL 8N KOH (positive control) for both the 3-minute and 1-hour time point.
REMOVAL OF TEST MATERIAL AND CONTROLS
After the exposure period, the tissues were washed with phosphate buffered saline to remove residual test material. The skin inserts were carefully dried. Rinsed tissues were kept in 24 well plates on 300 µL DMEM until 6 tissues (= one application time) were dosed and rinsed.
CELL VIABILITY MEASUREMENT
The DMEM was replaced by 300 µL MTT-medium and tissues were incubated for 3 hours at 37 °C in air containing 5 % CO2. After incubation the tissues were washed with PBS and formazan was extracted with 2 mL isopropanol overnight at room temperature. The amount of extracted formazan was determined spectrophotometrically at 570 nm in triplicate with the TECAN Infinite® M200 Pro Plate Reader.
ACCEPTABILITY CRITERIA
The in vitro skin corrosion test is considered acceptable if it meets the following criteria:
a) The absolute mean OD570 of the two tissues of the negative control should reasonably be within the laboratory historical control data range.
b) The mean relative tissue viability following 1-hour exposure to the positive control should be < 15 %.
c) In the range 20 - 100 % viability, the Coefficient of Variation (CV) between tissue replicates should be ≤ 30 %.
INTERPRETATION
A test material is considered corrosive in the in vitro skin corrosion test if:
a) The relative mean tissue viability obtained after 3-minute treatment compared to the negative control tissues is decreased below 50 %.
b) In addition, a test material considered non-corrosive (viability ≥ 50 %) after the 3-minute treatment is considered corrosive if the relative tissue viability after 1-hour treatment with the test item is decreased below 15 %.
A test material is considered non corrosive in the in vitro skin corrosion test if:
a) The relative mean tissue viability obtained after the 3-minute treatment compared to the negative control tissues is not decreased below 50 %.
b) In addition, the relative tissue viability after the 1-hour treatment is not decreased below 15 %. - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- TEST MATERIAL
- Amount(s) applied: 30.3 - 37.7 mg (with 25 µL Milli-Q water to increase tissue surface contact)
NEGATIVE CONTROL
- Amount(s) applied: 50 µL
POSITIVE CONTROL
- Amount(s) applied: 50 µL
- Concentration: 8.0 N - Duration of treatment / exposure:
- 3 minutes or 60 minutes
- Number of replicates:
- 2
Results and discussion
In vitro
Resultsopen allclose all
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 3 minute exposure
- Value:
- 100
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Irritation / corrosion parameter:
- % tissue viability
- Run / experiment:
- 60 minute expoure
- Value:
- 70
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- DIRECT MTT REDUCTION AND ASSESSMENT OF COLOUR INTERFERENCE
The test material was checked for colour interference in aqueous conditions and possible direct MTT reduction by adding the test material to MTT medium. Because the solutions did not turn blue / purple nor a blue / purple precipitate was observed it was concluded that the test material did not interfere with the MTT endpoint.
TEST MATERIAL AND CONTROLS
Mean OD570 values and viabilities for the negative control, positive control and test material are given in Table 1.
The relative mean tissue viability obtained after the 3-minute and 1-hour treatments with test material compared to the negative control tissues was 100 and 70 % respectively. Because the mean relative tissue viability for the test material was not below 50 % after 3 minutes treatment and not below 15 % after 1 hour treatment the test material is considered to be not corrosive.
QUALITY CRITERIA
The absolute mean OD570 (optical density at 570 nm) of the negative control tissues was within the acceptance limits of OECD 431 and the laboratory historical control data range. The mean relative tissue viability following the 1-hour exposure to the positive control was 7.9 %. In the range of 20 - 100 % viability the Coefficient of Variation between tissue replicates was ≤ 10 %, indicating that the test system functioned properly.
Any other information on results incl. tables
Table 1: Mean OD570 Values and Viabilities for the Negative Control, Positive Control and Test Material
Tissue |
Exposure period |
Mean OD570 of individual tissues |
Mean OD570 of duplicate tissues |
Standard deviation |
Coefficient of Variation (%) |
Relative Mean Viability (%) |
Negative control |
3 minutes |
1.579 |
1.643 |
0.090 |
7.4 |
100 |
1.706 |
||||||
60 minutes |
1.749 |
1.792 |
0.060 |
4.7 |
||
1.834 |
||||||
Positive control |
3 minutes |
0.153 |
0.149 |
0.005 |
5.0 |
9.1 |
0.146 |
||||||
60 minutes |
0.135 |
0.142 |
0.009 |
8.3 |
7.9 |
|
0.148 |
||||||
Test material |
3 minutes |
1.707 |
1.643 |
0.090 |
7.5 |
100 |
1.579 |
||||||
60 minutes |
1.178 |
1.246 |
0.096 |
10 |
70 |
|
1.314 |
OD = optical density
Applicant's summary and conclusion
- Interpretation of results:
- other: Not corrosive in accordance with EU criteria
- Conclusions:
- Under the conditions of the study, the test material was not corrosive in the in vitro skin corrosion test.
- Executive summary:
The potential of the test material to cause corrosion to the skin was determined in accordance with the standardised guidelines OECD 431 and EU Method B40.bis under GLP conditions using the EpiDerm™ Human Skin Model after treatment periods of 3 and 60 minutes.
During the study, duplicate tissues were treated with the test material for exposure periods of 3 and 60 minutes. Negative and positive control groups were treated for each exposure period.
Under the conditions of the study the positive control had a mean relative tissue viability of 7.9 % after the 1-hour exposure. The absolute mean OD570 (optical density at 570 nm) of the negative control tissues was within the acceptance limits of OECD 431 (lower acceptance limit ≥ 0.8 and upper acceptance limit ≤ 2.8) and the laboratory historical control data range. In the range of 20 - 100 % viability the Coefficient of Variation between tissue replicates was ≤10%, indicating that the test system functioned properly.
Skin corrosion is expressed as the remaining cell viability after exposure to the test material. The relative mean tissue viability obtained after 3-minute and 1-hour treatments with test material compared to the negative control tissues was 100 and 70 %, respectively. Because the mean relative tissue viability for the test material was not below 50 % after the 3-minute treatment and not below 15 % after the 1-hour treatment the test material is considered to be not corrosive.
In conclusion, the test material was not corrosive in the in vitro skin corrosion test.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.