Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-06-23
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In the preliminary test the substance could not be ignited after contact with a flame for 2 minutes. The test item could not be ignited with a flame. Therefore, no main test had to be done.

Interpretation of results:
GHS criteria not met
Conclusions:
The solid test substance is not highly flammable

Description of key information

The solid test substance is not highly flammable

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test item has not to be classified as readily combustible solid in accordance with Annex I, section 2.7 of Regulation (EC) No 1272/2008.