Endpoint:
thermal stability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 17, 2016 - June 23, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Test substance thermally stable:
yes
Remarks:
up to 300°C
Key result
Operating temp.:
>= 25 - <= 500 °C
Conclusions:
The test item Thiocure® TEMPIC showed an exothermic effect in the temperature range of approx. 300 – 380 °C, with an average decomposition energy of approx. -130 J/g, directly followed by an endothermic effect. No further effects could be detected up to the maximum temperature of 500 °C.

Executive summary:

The test item Thiocure® TEMPIC showed an exothermic effect in the temperature range of approx. 300 – 380 °C, with an average decomposition energy of approx. -130 J/g, directly followed by an endothermic effect. No further effects could be detected up to the maximum temperature of 500 °C.