Registration Dossier

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 Jun 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3219 (Plastics; polymers/resins in the liquid state or as emulsions or dispersions; determination of viscosity using a rotational viscometer with defined shear rate)
Version / remarks:
1994
Deviations:
no
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
5.13
Key result
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
3.06

Results


20 °C average = 5.10 mPa*s


20 °C average = 5.11 mPa*s


20 °C average = 5.18 mPa*s


overall average = 5.13 mPa*s


 


40 °C average = 3.08mPa*s


40 °C average = 3.00mPa*s


40 °C average = 3.10mPa*s


overall average = 3.06 mPa*s

Conclusions:
The dynamic viscosity of the test item was determined to be of 5.13 mPa/s at 20 °C.
Executive summary:

An experimental study was conducted to determine the dynamic viscosity of the test item according to OECD Test Guideline 114 and ISO 3219 using the rotational viscometer method. The dynamic viscosity of the test item was determined to be of 5.13 mPa/s at 20 °C and 3.06 mPa/s at 40 °C.

Description of key information

The dynamic viscosity of the test item was determined to be of 5.13 mPa/s at 20 °C.

Key value for chemical safety assessment

Viscosity:
5.13 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

An experimental study was conducted to determine the dynamic viscosity of the test item according to OECD Test Guideline 114 and ISO 3219 using the rotational viscometer method. The dynamic viscosity of the test item was determined to be of 5.13 mPa/s at 20 °C and 3.06 mPa/s at 40 °C.