Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Justification for type of information:
The analysis has been run on "Castor oil, sulfated, sodium salt" representative sample.
Please, see section 13.2 for further details justifing the read-across approach from this supporting substance.
Reason / purpose for cross-reference:
read-across source
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D6450
GLP compliance:
not specified
Type of method:
closed cup
Key result
Flash point:
> 200 °C
Atm. press.:
ca. 1 013 hPa

The test sample showed an extensive vapour emission at around 100°C. No flash point was identified up to 200°C. At the end of experiment the test sample was completely carbonized.

Conclusions:
Flash point has been determined using methods described by ASTM D6450 and found to be in excess of 200 deg C.
Executive summary:

Flash point has been determined using methods described by ASTM D6450 and found to be in excess of 200 deg C.

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D6450
GLP compliance:
not specified
Type of method:
closed cup
Key result
Flash point:
> 200 °C
Atm. press.:
ca. 1 013 hPa

The test sample showed an extensive vapour emission at around 100°C. No flash point was identified up to 200°C. At the end of experiment the test sample was completely carbonized.

Conclusions:
Flash point has been determined using methods described by ASTM D6450 and found to be in excess of 200 deg C.
Executive summary:

Flash point has been determined using methods described by ASTM D6450 and found to be in excess of 200 deg C.

Description of key information

Flash point: > 200 deg C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
200 °C

Additional information

Flash point has been determined on an analogue of teh substance (castor oil, sulfated, sodium salt) using methods described by ASTM D6450 and found to be in excess of 200 deg C.

Being the test item an analogue of the substance, this value is considered valid also for the substance (for more details, see section 13 - Similarity Report).