Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07 September 2017 to 08 September 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Reconstructed Human Epidermis (RHE) Test Method)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: Method B.40bis of Commission Regulation (EC) No 440/2008
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Bis(dodecylthio)dioctylstannane
EC Number:
244-841-3
EC Name:
Bis(dodecylthio)dioctylstannane
Cas Number:
22205-30-7
Molecular formula:
C40H84S2Sn
IUPAC Name:
bis(dodecylsulfanyl)dioctylstannane
Test material form:
liquid
Details on test material:
- Storage Conditions: Room temperature in the dark
- Physical state/Appearance: Colourless liquid

In vitro test system

Test system:
human skin model
Source species:
human
Cell type:
non-transformed keratinocytes
Justification for test system used:
Recommended in international guidelines
Vehicle:
unchanged (no vehicle)
Details on test system:
RECONSTRUCTED HUMAN EPIDERMIS (RHE) TISSUE
- Model used: EpiDerm™ Reconstructed Human Epidermis Model Kit
- Supplier: MatTek
- Tissue lot number: 25840
- Delivery date: 05 September 2017

TEST FOR DIRECT MTT REDUCTION
- A test material may interfere with the MTT endpoint if it was able to directly reduce MTT and at the same time was present on or in the tissues when the MTT viability test was performed. To identify this possible interference, the test material was checked for the ability to directly reduce MTT: 50 μL of the test material was added to 1 mL of a freshly prepared 1.0 mg/mL MTT solution. The solution was incubated in the dark at 37 °C, 5 % CO2 in air for 60 minutes. Untreated MTT solution was tested concurrently to act as a control. If the MTT solution containing the test material turns blue/purple relative to the control, the test material was presumed to have reduced the MTT.

ASSESSMENT OF COLOUR INTERFERENCE WITH THE MTT ENDPOINT
- A test material may interfere with the MTT endpoint if it is coloured or if it becomes coloured when in wet or aqueous conditions. The MTT assay is affected only if the test material is present in the tissues when the MTT viability assay is performed. 50 μL of test material was added to 300 μL of sterile water. The solution was incubated in the dark at 37 °C, 5 % CO2 in air for 60 minutes. A visual assessment of the colour was then made.

MAIN TEST
PRE-INCUBATION
- The assay medium was pre-warmed before use. 0.9 mL of this assay medium was pipetted into the appropriate wells of two pre-labelled 6-well plates for both the 3-minute and 60-minute exposure periods. EpiDerm™ tissues were transferred into the 6-well plates containing the assay medium. The 6-well plates containing the EpiDerm™ samples were pre-incubated (37 °C, 5 % CO2) for approximately 1 hour before dosing.

APPLICATION OF TEST MATERIAL
- Before pre-incubation was complete, a 24-well plate was prepared for use as a “holding plate” for both the 3-minute and 60-minute exposure periods. This plate was used to maintain the viability of the tissue inserts between rinsing following chemical exposure and MTT loading. Another 24-well plate was prepared for the MTT loading. 300 μL of either pre-warmed assay medium (holding plate) or MTT medium (MTT loading plate) was dispensed into each well. The two plates were placed into the incubator until required.
- After pre-incubation of the EpiDerm™ tissues, the medium was aspirated and replaced with 0.9 mL of fresh assay medium. The 6-well plate for the 3-minute exposure period was returned to the incubator, while the other was being dosed for the 60-minute exposure. For the 60-minute exposure period, 50 μL of sterile distilled water (negative control) was added to the first two tissues. The tissues were dosed at regular intervals to allow for the time taken to rinse each tissue following exposure and to ensure that each tissue gets an equal exposure time. 50 μL of the test material and 50 μL of 8.0 N potassium hydroxide (positive control) were also applied to the corresponding tissues in turn. The plate was returned to the incubator (37 °C, 5% CO2) for the 60-minute exposure period.
- When dosing for the 60-minute exposure period was complete, the same procedure was repeated for the 3-minute exposure period. Because the exposure time was so short, the tissues were dosed at regular intervals to ensure that each tissue received an equal exposure time and to allow for the time taken to rinse each tissue following exposure.

REMOVAL OF TEST MATERIAL AND CONTROLS AND MTT LOADING
- Rinsing was achieved by filling and emptying each tissue under a constant soft stream of Dulbecco’s Phosphate Buffered Saline (DPBS) to gently remove any residual test material. Excess DPBS was removed by blotting the bottom of the tissue insert with tissue paper. Each tissue was placed into the prepared holding plate until all tissues were rinsed. They were then blotted and transferred to the 24-well plate prepared for MTT loading. The plate was incubated (37 °C, 5% CO2) for 3 hours. Once the 60-minute exposure period was complete, the same rinsing and MTT loading procedure was repeated.
- After the 3-hour MTT incubation was complete, the inserts were blotted and transferred to labelled 24-well plates for MTT extraction. 2 mL of MTT extractant (isopropanol) was used to completely immerse each insert and the plate was covered with plate sealer to prevent isopropanol evaporation. The plates stood overnight at room temperature, to allow extraction to proceed.

TEMPERATURE USED FOR TEST SYSTEM
- Temperature used during treatment / exposure: 37 °C
- Temperature of post-treatment incubation (if applicable): 37 °C with MTT

ABSORBANCE/ OPTICAL DENSITY MEASUREMENTS
- After extraction, each tissue was pierced with a pipette fitted with a 1000 μL tip and the extraction solution was forced vigorously up and down to form a homogenous solution. 3 x 200 μL aliquots of the extract were transferred to the appropriate wells of a pre-labelled 96-well plate. 200 μL of isopropanol alone was added to the three wells designated as blanks. Absorbency at 570nm (OD570) of each well was measured using the Labtech LT-4500 microplate reader.

NUMBER OF REPLICATE TISSUES: 2 per exposure time

DATA EVALUATION
- Quantitative MTT Assessment (percentage tissue viability):
The corrosivity potential of the test material was predicted from the relative mean tissue viabilities obtained after the 3 and 60-minute exposure periods, compared to the mean of the negative control tissues (n=2) treated with sterile distilled water.
The relative mean viabilities were calculated in the following way:
Relative mean viability (%) = (mean OD570 of the test material/ mean OD570 of the negative control) x 100
Classification of corrosivity potential is based on relative viabilities for both exposure times according to the following:
STEP 1:
< 50 % viability after 3 min exposure = corrosive
≥ 50 % viability after 3 min exposure and < 15 % viability after 60 min exposure = corrosive
≥ 50 % viability after 3 min exposure and ≥ 15 % viability after 60 min exposure = non-corrosive
STEP 2 for test materials identified as corrosive in step 1:
< 25 % viability after 3 min exposure = H314 Sub-category 1A
≥ 25 % viability after 3 min exposure = H314 Combination of sub-categories 1B-and-1C

- Quality Criteria
The results of the assay are considered acceptable if the following assay acceptance criteria are achieved:
- The absolute OD570 of the negative control treated tissues in the MTT-test is an indicator of tissue viability obtained in the testing laboratory after the shipping and storing procedure and under specific conditions of the assay. The mean OD570 of the two negative control tissues should be ≥ 0.8 and ≤ 2.8 for each exposure time, which ensures that the tissue viability meets the acceptance criteria.
- Potassium hydroxide 8.0N solution is used as a positive control. An assay meets the acceptance criterion if mean relative tissue viability of the 60-minute positive control is < 15 %.
- In the range 20 and 100 % viability, the Coefficient of Variation between tissue replicates should be ≤ 30 %.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
TEST MATERIAL
- Amount(s) applied: 50 µL

NEGATIVE CONTROL
- Amount(s) applied: 50 µL

POSITIVE CONTROL
- Amount(s) applied: 50 µL
- Concentration: 8.0 N
Duration of treatment / exposure:
3 minutes of exposure and 1 hour of exposure
Duration of post-treatment incubation (if applicable):
Incubated for 3 hours with MTT
Number of replicates:
2 per exposure time

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 minute exposure period
Value:
95.1
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
60 minute exposure period
Value:
97.8
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
- Direct MTT Reduction: The MTT solution containing the test material did not turn blue/purple. This was taken to indicate the test material did not reduce MTT.

- Assessment of Colour Interference with the MTT endpoint: The solution containing the test material did not become coloured. This was taken to indicate the test material did not have the potential to cause colour interference.

- Test Material, Positive Control and Negative Control: Mean OD570 values and viabilities for the negative control, positive control and test material are given in Table 1.

- Quality Criteria:
The mean OD570 for the negative control treated tissues was 1.750 for the 3-minute exposure period and 1.746 for the 60-minute exposure period. The negative control acceptance criteria were therefore satisfied.
The relative mean tissue viability for the positive control treated tissues was 3.2 % relative to the negative control following the 60-minute exposure period. The positive control acceptance criterion was therefore satisfied.
In the range 20 to 100 % viability the Coefficient of Variation between the two tissue replicates of each treatment group did not exceed 30 %. The acceptance criterion was therefore satisfied.

Any other information on results incl. tables

Table 1: Mean OD570 Values and Viabilities for the Negative Control, Positive Control and Test Material

Tissue

Exposure Period

MeanOD570 of individual tissues

Mean OD570 of duplicate tissues

Standard Deviation

Coefficient of Variation
(%)

Relative Mean Viability (%)

Negative Control

3 Minutes

1.788

1.750

0.054

3.1

100*

1.711

60 Minutes

1.815

1.746

0.098

5.6

1.677

Positive Control

3 Minutes

0.069

0.065

0.006

na

3.7

0.061

60 Minutes

0.055

0.057

0.002

na

3.2

0.058

Test Material

3 Minutes

1.719

1.665

0.077

4.6

95.1

1.610

60 Minutes

1.700

1.708

0.011

0.7

97.8

1.716

OD = Optical density

* = The mean percentage viability of the negative control tissue is set at 100%

na = Not applicable

Applicant's summary and conclusion

Interpretation of results:
other: Not classified in accordance with EU Criteria
Conclusions:
Under the conditions of this study, the test material is not corrosive in the in vitro skin corrosion test.
Executive summary:

The potential of the test material to cause skin corrosion was investigated in accordance with the standardised guidelines OECD 431 and EU Method B.40bis, under GLP conditions.

The corrosivity potential of the test material was evaluated using the EpiDerm™ Human Skin Model after treatment periods of 3 and 60 minutes. Duplicate tissues were treated with the test material for exposure periods of 3 and 60 minutes. Negative and positive control groups were treated for each exposure period. At the end of the exposure period the test material was rinsed from each tissue before each tissue was taken for MTT-loading. After MTT loading each tissue was placed in 2 mL isopropanol for MTT extraction. At the end of the formazan extraction period each well was mixed thoroughly and triplicate 200 μL samples were transferred to the appropriate wells of a pre-labelled 96-well plate. The optical density (OD) was measured at 570 nm (OD570). Data are presented in the form of percentage viability (MTT reduction in the test material treated tissues relative to negative control tissues).  

The mean percentage viability of the test material treated tissues was 95.1 and 97.8 % after 3 and 60 minute exposure times, respectively. The quality criteria required for acceptance of results in the test were satisfied.

Under the conditions of this study, the test material is not corrosive in the in vitro skin corrosion test.