Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
2008
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Atm. press.:
1 020 hPa
Decomposition:
yes
Decomp. temp.:
>= 190 °C
Remarks on result:
not determinable

The recorded main weight loss above 252.1 °C (estimated onset on TGA) may indicate a beginning evaporation (boiling). However, based on the visual inspection and the results of the DSC preliminary test (up to 250°C) a product decomposition is more likely.

In order to provide evidence for this assumption, a degradation test was performed during which an aliquot of the sample was heated to 190 °C for 15 minutes. The remaining residue (98 % of the original material) war characterised by NMR spectroscopy. The NMR analysis confirms the decomposition of the product. A significant loss of carbonyl functions was detected.

Consequently, the test item does not provide a boiling point until disintegration at about 190 °C.

Conclusions:
Reaction product of lauryl-PDA/lauryl-DETA with chloroacetic acid does not have a boiling point until disintegration at about 190 °C.
Executive summary:

The boiling temperature of Reaction product of lauryl-PDA/lauryl-DETA with chloroacetic acid was determined by thermogravimetry and differential scanning calorimetry according to the OECD Test Guideline 103 [adopted on 27 July 1995] and EU test method A.2.

No boiling point could be detected; decomposition started above 190 °C (1020 hPa).

Description of key information

decomposition before boiling

Key value for chemical safety assessment

Additional information

The boiling temperature of Reaction product of lauryl-PDA/lauryl-DETA with chloroacetic acid was determined by thermogravimetry and differential scanning calorimetry according to the OECD Test Guideline 103 [adopted on 27 July 1995] and EU test method A.2.

No boiling point could be detected; decomposition started above 190 °C (1020 hPa).