Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 November 2017 - 22 December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Reason / purpose for cross-reference:
assessment report
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2016
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester”
Version / remarks:
2012
Deviations:
not specified
Principles of method if other than guideline:
According to ECA.9 the flash point can be determined by an equilibrium method or a non-equilibrium method. Several methods are mentioned in the guideline. ASTM D7094 is not one of the methods mentioned in the guideline but is a commonly used and safer (low sample volume) alternative for the non-equilibrium ISO 2719 Pensky martens closed cup method.
GLP compliance:
yes
Type of method:
other: modified continuously closed cup
Flash point apparatus:
other: Eraflash (Eralytics, Austria)
Dynamic viscosity of test material:
no data
Specific details on test material used for the study:
Decomposition temp.: 75°C
No boiling before decomposition.
Key result
Atm. press.:
1 013 hPa
Remarks on result:
other: no flash point was measured up to decomposition at 75°C

It was visually observed that the test item reacted and/or degraded at approximately 75°C. No flammable vapour/air mixture was produced at temperatures below the temperature at which reaction and/or degradation of the test item occurred. From this, it was concluded that the test item has no flash point. 

Interpretation of results:
other: not classified under CLP or GHS
Conclusions:
No flash point of the substance was observed before decomposition started (75°C).
Executive summary:

No flash point of the substance was observed before decomposition started (75°C) using the modified continuously closed cup ASTM D7094 method (GLP study).

Description of key information

No flash point of the substance was observed before decomposition started (75°C) using the modified continuously closed cup ASTM D7094 method.

Key value for chemical safety assessment

Additional information

No flash point before decomposition started (75°C).