Registration Dossier

Administrative data

Endpoint:
boiling point
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a solid which melts above 300°C
Cross-reference
Reason / purpose:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Remarks:
no GLP
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
27th July 1995
Deviations:
no
GLP compliance:
no
Type of method:
capillary method
Key result
Melting / freezing pt.:
> 320 °C
Atm. press.:
1 atm
Decomposition:
no
Remarks on result:
other: same result for measurement 1 & 2
Conclusions:
The study was performed according to OECD TG102 without deviations and therefore reliability of Klimisch 2 has been assigned. Melting point > 320 °C
Executive summary:

The melting point of the test material was determined to be > 320 °C using the capillary method in a non-GLP test according to OECD guideline 102.