Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15-19.09.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
yes
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Flash point:
> 100 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Conclusions:
The test substance has a flash point at 150°C at 1006 hPa
Executive summary:

The flash point of the Neodecanoic acid, tin(2 +) salt (2:1) was investigated in a study conducted according to ISO 2719:2002 (Determination of flash point - Pensky-Martens closed cup method).

The flash point was determined to be 150°C at 1006 hPa.