Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
not specified
Test procedure:
burning rate test: preliminary screening test
Burning time:
0 s
Moisture (wt %):
0.49
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

By the preliminary screening test (A10) the substance does not ignite and propagate combustion either by burning with flame or smoldering along 200 mm of the powder train within the test period. No further testing is required.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
By the preliminary screening test (A10, 1.6.1) the substance does not ignite and propagate combustion either by burning with flame or smoldering along 200 mm of the powder train within the test period. No further testing is required. The substance is not classified as flammable solid based on GHS criteria.
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be soluble in water to form a stable mixture
Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied

Description of key information

Zinc didocosanoate can be designated as not highly flammable, has no pyrophoric properties and does not emit flammable gases in contact with water.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Flammability of solids

By the preliminary screening test (A10) the substance does not ignite and propagate combustion either by burning with flame or smoldering along 200 mm of the powder train within the test period. No further testing is required. The substance is not classified as flammable solid based on GHS criteria.

Flammability in contact with water

The substance does not contain groups that might lead to a reaction with water or damp air, leading to the development of dangerous amounts of gas or gases which may be highly flammable. Furthermore, long-term industrial experience in practical handling of the substance shows that it does not react with water (cf. Section 1, Annex XI of Regulation (EC) 1907/2006).

Pyrophoric properties

The study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied. Zinc didocosanoate is stable at ambient temperature. It also does not contain any chemical groups that might lead to spontaneous ignition a short time after coming in contact with air at room temperature (ca. 20 °C). Furthermore, long-term industrial experience in handling shows that zinc didocosanoate does not ignite in contact with air (cf. Section 1, Annex XI of Regulation (EC) 1907/2006).

Justification for classification or non-classification

Zinc didocosanoate does not need to be classified according to CLP Regulation (EC) No 1272/2008 since it is not highly flammable.