Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 to 20 Jul 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. certificate)
Remarks:
Certificat de conformite aux bonnes pratiques de laboratoire selon les directives 2004/9/CE et 2004/10/CE
Auto-ignition temperature:
> 601 °C
Atm. press.:
978 hPa

Preliminary test

 

 

 

Injection No.

Volume of test item injected in the oven (µL)

 

Temperature

(°C)

 

Auto-ignition

Maximal temperature of the air recorded in the center of the test flask after auto-ignition (°C)

 

Atm pressure (kPa)

 

Relative humidity (%)

Observed

Corrected

Y / N

Lag (s)

Observed

Corrected

1

70

104

104

N

/

/

/

97.6

55

2

70

150

150

N

/

/

/

98.0

52

3

70

201

201

N

/

/

/

98.0

52

4

70

247

247

N

/

/

/

98.0

53

5

70

295

295

N

/

/

/

98.0

54

6

70

347

347

N

/

/

/

98.0

53

7

70

403

403

N

/

/

/

98.0

52

8

70

453

453

N

/

/

/

98.0

52

9

70

501

501

N

/

/

/

98.0

52

10

70

554

554

N

/

/

/

98.0

51

11

90

564

564

N

/

/

/

98.0

48

12

110

564

564

N

/

/

/

98.0

45

13

130

564

564

N

/

/

/

98.0

43

14

150

564

564

N

/

/

/

98.0

43

15

170

564

564

N

/

/

/

97.9

43

16

190

564

564

N

/

/

/

97.8

43

 

This first part was performed with an oven which did not reach 600 °C. Complementary assays were made with another oven.

 

 

 

Injection No.

Volume of test item injected in the oven (µL)

 

Temperature

(°C)

 

Auto-ignition

Maximal temperature of the air recorded in the center of the test flask after auto-ignition (°C)

 

Atm pressure (kPa)

 

Relative humidity (%)

Observed

Corrected

Y / N

Lag (s)

Observed

Corrected

1

70

600

601

N

/

/

/

97.8

37

2

90

600

601

N

/

/

/

97.8

37

3

110

600

601

N

/

/

/

97.8

37

4

130

600

601

N

/

/

/

97.8

38

5

150

600

601

N

/

/

/

97.8

38

6

170

600

601

N

/

/

/

97.8

39

7

190

600

601

N

/

/

/

97.8

39

Main test

Taking into account the results obtained during the preliminary assay, no main test was performed.

 

Conclusion

Only a preliminary test was performed: No auto-ignition temperature was observed up to 601 °C (corrected value).

Conclusions:
No auto-ignition temperature was observed up to 601 °C at 980 hPa in a reliable study conducted according to an appropriate test protocol.

Description of key information

Trichloro(4-methylphenyl)silane: > 601 °C at 980 hPa (EU method A.15)

Key value for chemical safety assessment

Additional information