Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
13 Nov 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The Limit of Quantification of the method used is higher than expected based on OECD Guideline 104.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
March 23, 2006
Deviations:
no
GLP compliance:
yes
Type of method:
static method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
solid: particulate/powder

Results and discussion

Vapour pressureopen allclose all
Temp.:
25 °C
Vapour pressure:
< 133 Pa
Remarks on result:
other: LOQ of the method is 133 Pa
Temp.:
50 °C
Vapour pressure:
< 133 Pa
Remarks on result:
other: LOQ of the method is 133 Pa

Any other information on results incl. tables

The value was regarded as <133 Pa because the vapour pressure was under the limit of quantification.

Applicant's summary and conclusion