Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-07-14 - 2016-07-29
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Department of Health of the Government of the United Kingdom
Key result
Sample tested:
other: no explosiv properties because of structure
Parameter:
other: no explosiv properties because of structure
Remarks on result:
other: no oxidising properties because of structure

There are no structural alerts within the chemical structure of the test item.

Interpretation of results:
other: EU GHS criteria not met
Conclusions:
Based on the chemical structure of the test item the result for the oxidizing properties has been predicted negative.
Executive summary:

Oxidising Properties (Liquids). Predicted negative based on the chemical structure of the test item, using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Description of key information

Oxidising properties_Prediction compatible with EU Method A.21: none

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Oxidising Properties (Liquids). Predicted negative based on the chemical structure of the test item, using a procedure designed to be compatible with Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Justification for classification or non-classification

The test substance possesses no chemical groups that imply oxidizing properties. Therefore, the substance is classified as non-oxidizing in accordance with Regulation (EC) No 1272/2008.