Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 Oct 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 116B2018
- Physical state: colourless liquid
- Purity:96.7%
- Purity test date: 9 August 2016
- Expiration date of the lot/batch: 31 March 2018

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature (10 °C to 30 °C)
Key result
Flash point:
30 °C
Atm. press.:
1 013 hPa

In the main test, the test material ignited at 30.5 °C but did not ignite at 30.0 °C at 1020.8 hPa. The flash point was corrected to a pressure of 1013 hPa using the formula:

Flp. = C + 0.025 (1013 - p)

where FLP.: flash point corrected to 1013 hPa in °C

C: measured flash point in °C

p: ambient pressure in hPa

According to the guideline, the temperaturefor the final flash point is rounded down with an accuracy of 0.5 °C. The lowest flash point corrected to 1013 hPa was 30.3 °C and by rounding down to the nearest 0.5 °C, was determined as 30.0 °C.

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash point of PPVE-2 was 30.0 °C under atmospheric conditions (1013 hPa) according to EU Method A.9.
Executive summary:

The flash point of PPVE-2 was tested using a closed-cup method. In the main test, the flash point was determined with temperature steps of 0.5 K. The test material ignited at 30.5 °C but did not ignite at 30.0 °C at 1020.8 hPa. The lowest flash point corrected to 1013 hPa was rounded down to the nearest 0.5 °C, and was determined as 30.0 °C. The study was conducted in accordance with EU Method A.9 and was GLP compliant; therefore the study is considered reliable without restrictions.

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment
Qualifier:
no guideline followed
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
>= 93.3 °C
Interpretation of results:
study cannot be used for classification
Conclusions:
The flash point of PPVE-2 is ≥ 93.3 °C using a closed cup method.
Executive summary:

The flash point of PPVE-2 is ≥ 93.3 °C using a closed cup method. Only the result was reported on the SDS and no information about the pressure or method details were provided; therefore the reliability of the data is not assignable.

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
12 Sep 2001
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Deviations:
yes
Remarks:
The test substance is solid and was tested only up to 93°C (200°F). The test method is intended for liquids with a flash point between 0 and 110°C (32 and 230°F).
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
>= 93 °C

No flash was detected at any tested temperature. The highest temperature tested for flash was 93 °C (200 °F).

Interpretation of results:
study cannot be used for classification
Conclusions:
The flash point of PPVE-2 is ≥ 93.3 °C using a closed cup method (ASTM D-3278).
Executive summary:

The flash point of PPVE-2 was tested using a closed cup flash-point apparatus. The test was performed at specific temperatures of 53 °F, 70 °F, 100 °F, and 200 °F. No flash was observed up to the highest temperature tested (93 °C or 200 °F). This study was conducted in accordance with ASTM D-3278 but is not compliant with GLP standards. Also, the test guideline calls for flash point to be tested up to 110 °C for flash/no flash. Therefore the study is classified as reliable with restrictions.

Description of key information

The flash point of PPVE-2 was 30.0 °C under atmospheric conditions (1013 hPa) according to EU Method A.9.

Key value for chemical safety assessment

Additional information

In the key study, the flash point of PPVE-2 was tested using a closed-cup method. The flash point was determined with temperature steps of 0.5 K. The test material ignited at 30.5 °C but did not ignite at 30.0 °C at 1020.8 hPa. The lowest flash point corrected to 1013 hPa was rounded down to the nearest 0.5 °C, and was determined as 30.0 °C. The study was conducted in accordance with EU Method A.9 and was GLP compliant; therefore the study is considered reliable without restrictions. In a supporting study, the flash point of PPVE-2 was tested using a closed cup flash-point apparatus. The test was performed at specific temperatures of 53 °F, 70 °F, 100 °F, and 200 °F. No flash was observed up to the highest temperature tested (93 °C or 200 °F). This study was conducted in accordance with ASTM D-3278 but is not compliant with GLP standards. Also, the test guideline calls for flash point to be tested up to 110 °C for flash/no flash. Therefore the study is classified as reliable with restrictions. An additional study reported the flash point of PPVE-2 as ≥ 93.3 °C using a closed cup method. Only the result was reported on the SDS and no information about the pressure or method details were provided; therefore the reliability of the data is not assignable.