Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Version / remarks:
2013
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
N,N''-hexane-1,6-diylbis[N'-(2-hydroxyethyl)-N'-methylurea]
EC Number:
253-281-9
EC Name:
N,N''-hexane-1,6-diylbis[N'-(2-hydroxyethyl)-N'-methylurea]
Cas Number:
36938-15-5
Molecular formula:
C14H30N4O4
IUPAC Name:
2-(3-{6-[3-(2-Hydroxyethyl)-3-methylureido]hexyl}-1-methylureido)ethanol
Constituent 2
Chemical structure
Reference substance name:
6-[3-(2-Hydroxyethyl)-3-methylureido]hexylamino 3-(methylamino)propionate
Molecular formula:
C14H30N4O4
IUPAC Name:
6-[3-(2-Hydroxyethyl)-3-methylureido]hexylamino 3-(methylamino)propionate
Test material form:
solid: bulk
Details on test material:
- Batch no.: EGGE 2806-1
- Currenta sample no.: 2187
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: room temperature
- Solubility and stability of the test substance in the solvent/vehicle: Analytical determination of stability and homogeneity of the test item in the vehicle was not performed specifically for this study.
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: The usage of physiological saline solution for formulation of the test item is plausible based on the current knowledge of the sponsor. No objections were seen particularly in regard to stability.


TREATMENT OF TEST MATERIAL PRIOR TO TESTING

- Final dilution of a dissolved solid, stock liquid or gel: The test item was solved shortly prior to application in physiologic saline solution to achieve a concentration of 20 % (w/v).

FORM AS APPLIED IN THE TEST (if different from that of starting material): The preparation was visually described as solution (slight turbidity).

Test animals / tissue source

Species:
cattle
Strain:
other: not applicable
Details on test animals or tissues and environmental conditions:
Bovine eyes of slaughtered cattle were extracted and transferred in containers with Hank’s balanced salt solution (HBSS) with penicillin/streptomycin solution. For transportation the containers were ice cooled.
Eyes with defects were sorted out and disposed of, eyes without any defects were transferred into fresh HBSS supplemented with penicillin/streptomycin solution and 1 % FBS and stored overnight at 2-8 °C. On the next day (day of testing) the containers with the eyes were placed in an incubator at 32 ° C (± 1 ° C) for about 2 hours before preparation of the corneas.

Test system

Vehicle:
physiological saline
Controls:
yes, concurrent vehicle
yes, concurrent positive control
Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 750 µl per cornea and chamber
-Concentration: 20% (w/v)

VEHICLE
- Amount(s) applied (volume or weight with unit): 750 μL per cornea and chamber
- Concentration (if solution): 0.9% NaCl (w/v)

Duration of treatment / exposure:
4 hours
Duration of post- treatment incubation (in vitro):
no further incubation required
Number of animals or in vitro replicates:
three
Details on study design:
Details on study design:
Immediately before application, the medium was aspirated from the anterior chamber. 750 μL of the test material formulations were applied to the corneas, each through the holes of the anterior chamber. The holes of both chambers were sealed with adhesive tape and the holders were kept with the front side up, so that the formulations covered the cornea sufficiently (closed chamber method). The holders were transferred into the incubator at 32 °C (± 1 °C) for the exposure time of 4 hours. After the exposure, the formulations were aspirated from the anterior chamber and the corneas were rinsed at least 3 times with phenol red containing MEM to show effectiveness of test substance removal. During the final rinse cycle the corneas were rinsed again with pure MEM medium in order to remove residues of the dye. The anterior chamber was then filled again with MEM medium to avoid drying out of the cornea. Before measuring opacity, fresh MEM medium was filled in the chambers and the holes were sealed with tape.

Positive control: 20 % Imidazole in physiologic saline (w/v; 750 μL)

TREATMENT METHOD: closed chamber

POST-INCUBATION PERIOD: no

METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: The opacity of a cornea was measured by the diminution of light passing through the cornea. The measurements of opacity were carried out using an opacitometer BASF OP3.0 (with integrated light meter testo 545 and Comfort 3.4 SP6 software from Testo AG, Lenzkirch). Before each measurement the opacitometer was adjusted to about 1000 LUX and a filter calibration measurement was carried out by using 3 different filters.
- Corneal permeability:The medium in anterior chamber of each holder was replaced by 1ml of fluorescein sodium solution (concentration 5 mg/mL). Afterwards the holders were incubated at 32 °C (± 1 °C) for about 90 minutes. After the incubation period, the medium of the posterior chamber was aspirated by a syringe and filled into a 10 mL tube. Three wells of a 96 well plate were filled with 300 μL of each tube (triplicate determination). In addition, a standard series of 5 mg/mL sodium fluoresceinsolution was prepared and also filled into the 96-well plate, in triplicates. The permeability was determined by measuring the amount of fluorescein sodium which diffused through all cell layers of the cornea. The measurement was carried out at a wavelength of 490 nm (OD490) by an ELISA - Reader (Bio-Tek EL 808, Software Gen5).

SCORING SYSTEM: In Vitro Irritancy Score (IVIS)

DECISION CRITERIA:decision criteria as indicated in the OECD TG 437

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Remarks:
(IVIS)
Run / experiment:
mean
Value:
-4.1
Vehicle controls validity:
valid
Negative controls validity:
not applicable
Positive controls validity:
valid

Any other information on results incl. tables

Table 1: Individual values of opacity, permeability and IVIS

 Cornea No.  Opacity per cornea Permeability per cornea  IVIS per cornea

 IVIS per group

mean

 IVIS per group

SD

 Vehicle control 0.9% NaCl

1  -2.4  0.007  -2.3  
   2 1.5   0 .013  1.7  0.0  2.1
   3  0.5  0.006  0.6    
 Positive control 20% Imidazole  4  71.0  0.849  83.7    
   5  83.5  0.667  93.5  91.4  6.9
   6  81.2  1.058  97.1    
 Test item  7  -3.6  0.006  -3.5    
   -5.2  0.000  -5.2  -4.1  1.0
   9  -3.5  0.000  -3.5    

Applicant's summary and conclusion

Interpretation of results:
other: negative
Executive summary:

The test item (20 % (w/v) in physiologic saline) was tested in the BCOP test according to OECD TG 437. For determination of corneal damage opacity as well as tissue permeability was measured after a 4 hour exposure time. Based on these data, in comparison to the vehicle control, the In Vitro Irritancy Score (IVIS) value was calculated to be -4.1 which is below the IVIS cut-off threshold of 55 and thus identifying the test item as not inducing serious eye damage. The results of the positive (20 % imidazole solution) and vehicle (physiologic saline solution) controls confirmed the validity of the test system.