Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 Jan - 08 Feb 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 09892701
- Expiration date of the lot/batch: 06 Mar 2018
- Purity: 99%
- Storage conditions: room temperature, in the dark
- Appearance/physical state: clear colourless liquid

Results and discussion

Vapour pressure
Key result
Temp.:
ca. 25 °C
Vapour pressure:
ca. 6.8 Pa

Applicant's summary and conclusion

Conclusions:
The vapor pressure of test item has been determined to be 6.8 Pa at 25 °C.