Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29 Jul 2017 - 10 Jan 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.3 (Relative Density)
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. certificate)
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 09892701
- Expiration date of the lot/batch: 06 Mar 2018
- Purity: 99%
- Storage conditions: room temperature, in the dark
- Appearance/physical state: clear colourless liquid

Results and discussion

Densityopen allclose all
Key result
Type:
relative density
Density:
ca. 1.06 other:
Temp.:
20 °C
Key result
Type:
bulk density
Density:
ca. 1 060 kg/m³
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The density of the test item has been determined to be 1.06 x 103 kg/m3 at 20.0 ± 0.5 °C;
relative density value: 1.06.