Registration Dossier

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
not specified
GLP compliance:
no
Type of method:
pycnometer method
Key result
Type:
relative density
Remarks:
mean of replicates
Density:
1.853 g/cm³
Temp.:
20 °C

Resuls of individual measurements:

- Replicate 1: 1.8532 g/cm^3

- Replicate 2: 1.8653 g/cm^3

- Replicate 3: 1.8392 g/cm^3

Conclusions:
In a study performed according to EC440/2008-A.3. the relative density of Potassium ferrocyanide at 20°C was determined to be 1.8526 g/cm^3.

Description of key information

In a study performed according to EC440/2008-A.3. the relative density of Potassium ferrocyanide at 20°C was determined to be 1.8526 g/cm^3.

Key value for chemical safety assessment

Relative density at 20C:
1.853

Additional information