Registration Dossier

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
density, other
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D4052
GLP compliance:
not specified
Type of method:
oscillating densitimeter
Specific details on test material used for the study:
Batch Identifier: 2736469
Expiry Date: 01-Mar-2020
Key result
Type:
density
Density:
1.717 g/cm³
Temp.:
25 °C
Conclusions:
MTDID 22327 has a density of 1.717 g/cm3 at 25°C.
Executive summary:

MTDID 22327 has a density of 1.717 g/cm3 at 25 °C. The result was reported on a certificate of analysis and was determined using an oscillating densitometer with a method equivalent or similar to ASTM D 4052. The result is considered reliable with restrictions and suitable for Risk Assessment, Classification and Labeling.

Endpoint:
relative density
Type of information:
not specified
Adequacy of study:
supporting study
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment
Qualifier:
no guideline followed
GLP compliance:
no
Key result
Type:
relative density
Density:
1.75
Conclusions:
MTDID 22327 has a relative density of 1.75.
Executive summary:

MTDID 22327 has a relative density of 1.75. Only the result was reported on the SDS and no information about the method used was provided; therefore the reliability of the data is not assignable.

Description of key information

MTDID 22327 has a density of 1.717 g/cm3 at 25°C.

Key value for chemical safety assessment

Additional information

In the key study, the density of MTDID 22327 was determined using an oscillating densitometer with a method equivalent or similar to ASTM D 4052. The result was reported on a certificate of analysis and is considered reliable with restrictions and suitable for Risk Assessment, Classification and Labeling. In a supporting study, a relative density of 1.75 was reported for MTDID 22327. Only the result was reported on the Safety Data Sheet and no information about the method used was provided; therefore the reliability of the data is not assignable.