Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-08-16 - 2018-02-02
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
99 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
The test item Thioglycerol has a flash point of 99.0 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 3679 (2004).

Executive summary:

The test item Thioglycerol has a flash point of 99.0 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point and DIN EN ISO 3679 (2004).

Description of key information

The test item Thioglycerol has a flash point of 99.0 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point andDIN EN ISO 3679 (2004).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
99 °C

Additional information