Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 947-660-4 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- The study was conducted between 22 September 2016 and 31 October 2016.
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient - HPLC Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7570 (Partition Coefficient, n-octanol / H2O, Estimation by Liquid Chromatography)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- Lot No.: SC00012329
Aspect: yellow to brownish yellow liquid - Analytical method:
- high-performance liquid chromatography
- Type:
- log Pow
- Partition coefficient:
- 2
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 1.7% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 2.6
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 7.3% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 3
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 5.9% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 3.6
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 4.3% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 4
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 5.6% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 4.3
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 9.7% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 4.6
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 30.3% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 4.8
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 2.2% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 4.8
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 4.0% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 5.3
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 1.5% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 5.4
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 9.1% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 5.5
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 1.2% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 5.7
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 4.0% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 5.9
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 1.0% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 6
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 2% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 6.3
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 1.5% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 6.4
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 3.4% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 7.2
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 1.9% relative peak area
- Type:
- log Pow
- Partition coefficient:
- 7.6
- Temp.:
- 35 °C
- pH:
- 7
- Remarks on result:
- other: 3.4% relative peak area
- Conclusions:
- The chromatograms of Citrathal Concentrate S TW (an UVCB substance) show nineteen peaks with relative peak areas over 1% at average retention times of 3.23 minutes (1.7 % relative peak area), corresponding to a partition coefficient (log value) of 2.0; 3.70 minutes (7.3 % relative peak area) corresponding to a partition coefficient (log value) of 2.6; 4.26 minutes (5.9% relative peak area) corresponding to a partition coefficient (log value) of 3.0; 5.40 minutes (4.3% relative peak area) corresponding to a partition coefficient (log value) of 3.6; 6.38 minutes (5.6% relative peak area) corresponding to a partition coefficient (log value) of 4.0; 7.39 minutes (9.7% relative peak area) corresponding to a partition coefficient (log value) of 4.3; 8.29 minutes (30.3% relative peak area) corresponding to a partition coefficient (log value) of 4.6; 9.18 minutes (2.2% relative peak area) corresponding to a partition coefficient (log value) of 4.8; 9.37 minutes (4.0% relative peak area) corresponding to a partition coefficient (log value) of 4.8; 12.00 minutes (1.5% relative peak area) corresponding to a partition coefficient (log value) of 5.3; 12.86 minutes (9.1% relative peak area) corresponding to a partition coefficient (log value) of 5.4; 13.58 minutes (1.2% relative peak area) corresponding to a partition coefficient (log value) of 5.5; 15.44 minutes (4.0% relative peak area) corresponding to a partition coefficient (log value) of 5.7; 17.86 minutes (1.0% relative peak area) corresponding to a partition coefficient (log value) of 5.9; 19.14 minutes (2.0% relative peak area)corresponding to a partition coefficient (log value) of 6.0; 22.09 minutes (1.5% relative peak area) corresponding to a partition coefficient (log value) of 6.3; 23.65 minutes (3.4% relative peak area) corresponding to a partition coefficient (log value) of 6.4; 39.88 minutes (1.9% relative peak area) corresponding to a partition coefficient (log value) of 7.2 and 53.52 minutes (3.4% relative peak area) corresponding to a partition coefficient (log value) of 7.6.
Therefore:
Partition coefficient n-octanol/water of Citrathal Concentrate S TW: Log Pow = 2.0; 2.6; 3.0; 3.6; 4.0; 4.3; 4.6; 4.8; 4.8; 5.3; 5.4; 5.5; 5.7; 5.9*; 6.0*; 6.3*; 6.4*; 7.2*; 7.6*
* = indicative values, peaks are outside calibration domain. - Executive summary:
The partition coefficient n-octanol/water of Citrathal Concentrate S TW was determined by the Reverse Phase High Performance Liquid Chromatographic Method according to the OECD Guidelines for Testing of Chemicals, Method No. 117.
The result is:
Partition coefficient n-octanol/water of Citrathal Concentrate S TW: Log Pow = 2.0; 2.6; 3.0; 3.6; 4.0; 4.3; 4.6; 4.8; 4.8; 5.3; 5.4; 5.5; 5.7; 5.9*; 6.0*; 6.3*; 6.4*; 7.2*; 7.6*
* = indicative values, peaks are outside calibration domain.
Reference
Description of key information
The log Pow of the substance (an UVCB substance) has been determined using the HPLC method (GLP-compliant study in accordance with OECD 117). The chromatogram of Citrathal Concentrate S TWs showed 19 peaks with relative peak areas over 1%. The Log Kow values range from 2 to 7.6.
Key value for chemical safety assessment
Additional information
For the purposes of environmental exposure and risk assessment a partition coefficient range derived for the whole substance will be meaningless. Thus data for individual known constituents has been gathered (see supporting studies for assessment entities). Based on this information, the measured values obtained from the determination performed on the whole substance can be tentatively assigned to the following constituent types, although it is recognised that there may be some overlap at the boundaries between the different groups: C10-C12 oxygenated compounds (peaks 1-4, log Kow 2 – 3.6, 19.2% total peak area); C7-C10 hydrocarbons (peaks 5-11, log Kow 4 to 5.4; 62.4% total peak area) and higher MW unknowns (peaks 12-19, Log kow 5.5 to 7.6, 18.4% total peak area). For the purpose of the PBT assessment, peaks with a log Kow of > 4.5 (potentially fulfils the B/vB criteria) make up 65.5% total relative peak area of the tested substance.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.