Registration Dossier

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
oxidising liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
oxidising solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the organic substance contains oxygen or halogen atoms which are chemically bonded only to carbon or hydrogen and hence, the classification procedure does not need to be applied

Description of key information

The test item has not to be classified as oxidising solid, oxidising liquid or oxidising gas.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

TEMPLATE

Justification for classification or non-classification

Based on the chemical structure, the test item is not considered to be classified for oxidising properties according to Regulation (EC) No 1272/2008.