Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Qualifier:
according to
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
no
Contact with:
powdered cellulose
Sample tested:
test mixture (not specified)
Remarks:
migrated information
Parameter:
maximum burning rate
Remarks on result:
other: result not specified (migrated information)
Remarks:
No mixture of the test item ignited and therefore no burning rate could be determined.
Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
All mixtures of test item and cellulose did not ignite and showed no signs of oxidising properties. Therefore the test item is considered to have no oxidising properties.
Executive summary:

Oxidising properties were conducted according to EU Method A.17.

Under experimental conditions, all mixtures of test item and cellulose did not ignite and showed no signs of oxidising properties. Therefore the test item is considered to have no oxidising properties.

Description of key information

Oxidising properties were conducted according to EU Method A.17.

Under experimental conditions, all mixtures of test item and cellulose did not ignite and showed no signs of oxidising properties. Therefore the test item is considered to have no oxidising properties.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Justification for classification or non-classification