Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 June 2020 - 24 August 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
> 6.5
Temp.:
30 °C
pH:
ca. 3
Details on results:
Mean log10 Pow: >6.5
Partition coefficient: >3.16 x 10E6 (see attached report for details)

DISCUSSION
The result from the preliminary test indicated that the HPLC method was suitable for determination of partition coefficient for this test item.

The mobile phase was adjusted to pH 3 to ensure any protonated nitrogen species (amines) in the test item would not have any significant secondary interaction with anionic silanol groups on the stationary phase of the column.
Conclusions:
The partition coefficient of the test item has been determined to be greater than 3.16 x 10E6, log10 Pow >6.5.
Executive summary:

The determination was carried out by the HPLC Method, using a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.


The test system consisted of a high performance liquid chromatograph with an appropriate detector. A reverse phase HPLC column with a very low percentage of polar groups was used and the mobile phase contained at least 25% aqueous phase.


The partition coefficient of the test item has been determined to be greater than 3.16 x 10^6, log10 Pow >6.5.

Description of key information

The partition coefficient (log Pow) of EC n° 701 -204 -9 has been evaluated using the HPLC method (OECD 117). Log Pow (weighted average) of >6.5 has been determined using polycyclic aromatic hydrocarbons as retention time calibrants.

Key value for chemical safety assessment

Log Kow (Log Pow):
6.5
at the temperature of:
30 °C

Additional information

The partition coefficient (log Pow) of EC n° 701-204-9 has been evaluated using the HPLC method (OECD 117).

The partition coefficient of the test item has been determined to be greater than 3.16 x 106, log10 Pow >6.5.