Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: European Commission Regulation (EC) No. 440/2008, Method A. 10
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10.

Description of key information

The test item is not highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10. The test item could not be ignited with a flame. The test item discoloured to black during contact the flame.

Key value for chemical safety assessment

Additional information

The test item could not be ignited with a flame.The test item discoloured to black during contact the flame.

The performance of the main test was not necessary.

Justification for classification or non-classification

The test item is not a highly flammable solid in the sense of the European Commission Regulation (EC) No. 440/2008, Method A.10.