Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05.07.09.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
no
Type of method:
effusion method: Knudsen cell
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0 Pa
Test no.:
#3
Temp.:
50 °C
Vapour pressure:
0 Pa

The vapour pressure was measured in the temperature range of 80 °C to 105 °C. After the measurement a mass loss of approx. 8 % (w/w) was determined. A molecular mass of 376.53 g/mol was used for the evaluation.

Measured vapour pressures and corresponding temperatures

Temperature / °C

Vapour pressure / hPa

80

2.4 x -10-5

85

6.1 x 10-5

90

1.1 x 10-4

95

1.9 x 10-4

100

3.3 x 10-4

105

5.6 x 10-4

95

2.0 x 10-4

 

The values for 20, 25 and 50 °C are calculated, using the Antoine constants A, B and C

Conclusions:
The vapour pressure of the test item at 25 °C was determined to be 4.9E-7Pa.
Executive summary:

A study was conducted according to OECD TG 104, Regulation (EC) No 440/2008 method A.4 and OPPTS 830.7950 to determine the vapour pressure of the test item. The vapour pressure of the test item was determined in the temperature range 80 -105°C. After the measurement a mass loss of approx. 8 % (w/w) was determined. A molecular mass of 376.53 g/mol was used for the evaluation. The values for 20, 25 and 50°C are calculated, using the Antoine constants A, B and C. The vapour pressure of the test item was determined to be 1.9E-7 Pa at 20°C, 4.9E-7 Pa at 25°C and 3.5E-5 Pa at 50°C respectively.

Description of key information

The vapour pressure of the test item at 25 °C was determined to be 4.9E-7Pa (reference 4.6 -1).

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information

A study was conducted according to OECD TG 104, Regulation (EC) No 440/2008 method A.4 and OPPTS 830.7950 to determine the vapour pressure of the test item. The vapour pressure of the test item was determined in the temperature range 80 -105°C. After the measurement a mass loss of approx. 8 % (w/w) was determined. A molecular mass of 376.53 g/mol was used for the evaluation. The values for 20, 25 and 50°C are calculated, using the Antoine constants A, B and C. The vapour pressure of the test item was determined to be 1.9E-7 Pa at 20°C, 4.9E-7 Pa at 25°C and 3.5E-5 Pa at 50°C respectively.