Registration Dossier

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04.-07.07.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Boiling point
Boiling pt.:
>= 403 - <= 405 °C
Atm. press.:
1 013 hPa
Decomposition:
no

Applicant's summary and conclusion

Executive summary:

The substance showed a boiling point in the range of 403 -405°C.