Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07.01.2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Percentile:
D10
Mean:
5.3 µm
Remarks on result:
other: SD not indicated
Percentile:
D50
Mean:
29.3 µm
Remarks on result:
other: SD not indicated
Percentile:
D90
Mean:
791.8 µm
Remarks on result:
other: SD not indicated
Executive summary:

The median particle size of the test substance was 29.3 µm.

Description of key information

Additional information