Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Justification for type of information:
Specification data long held by the manufacturer. Practical handling experience has not resulted in the questioning of the accuracy of this data
Reference:
Composition 0
Qualifier:
equivalent or similar to
Guideline:
ASTM D1310 (Standard test method for flash point and fire point of liquids by tag open-cup apparatus)
Principles of method if other than guideline:
Tag open cup
GLP compliance:
not specified
Type of method:
open cup
Flash point apparatus:
Tag apparatus
Test material information:
Composition 1
Key result
Flash point:
137 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: assume standard atmospheric pressure

The flash point of the test material was found to be 137oC in an open cup apparatus.

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test material was found to be 137°C at standard atmospheric pressure.

Description of key information

137 oC (tag open cup)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
137 °C

Additional information