Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
(Q)SAR
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
EPI Suite version 4.11

2. MODEL (incl. version number)
Mpbpwin v. 1.43

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
See “Test material information”

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
See attached information on the model provided by the developer. Further information on the OECD criteria as outlined by the applicant is provided below under "Any other information of materials and methods incl. tables"

5. APPLICABILITY DOMAIN
See attached information and information as provided in "Any other information on results incl. tables".

6. ADEQUACY OF THE RESULT
See assessment of adequacy as outlined in the "Overall remarks, attachments" section.
Qualifier:
according to guideline
Guideline:
other: REACH Guidance on QSARs R.6
Principles of method if other than guideline:
- Software tool(s) used including version: EPI Suite v4.11
- Model(s) used: Mpbpwin Model version 1.43
The model is based on the Atom/Fragment Contribution (AFC) method from the work of Meylan and Howard (W.M. Meylan and P.H. Howard, Atom/fragment contribution method for estimating octanol-water partition coefficients, 1995, J. Pharm. Sci. 84: 83-92.), as implemented in the EPI Suite KOWWIN module (http://www.epa.gov/oppt/exposure/pubs/episuite.htm). The calculated model has a lower bound of -5.0 log units (all predictions lower than this value are set to -5.0). A dataset of compounds with experimental logP values has been built starting from the original dataset provided in EPI suite. The set has been processed and cleared from compounds that were replicated or that had problems with the provided molecule structure. The final dataset has 9,961 compounds.
- Model description: see field 'Justification for type of information', 'Attached justification' and 'any other information on Material and methods'
- Justification of QSAR prediction: see field 'Justification for type of information', 'Attached justification' and/or 'overall remarks'
GLP compliance:
no
Type of method:
other: QSAR
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Modified Grain method

QSAR result; transition/decomposition is not specified/reported. For detailed description of the model and its applicability, see "Any other information on materials and methods incl. tables”

Description of key information

2.58E-007 Pa at 25 °C (Modified Grain Method, Mp = 133 °C) calculated with EpiSuite.

Key value for chemical safety assessment

Additional information