Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2015-06-23
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted according to an appropriate OECD test guideline. It was not compliant with GLP.
Qualifier:
according to guideline
Guideline:
DIN 51562 Part 1 (Viscometry - Measurement of kinematic viscosity by means of the Ubbelohde viscometer - Part 1: Viscometer specification and measurement procedure)
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2008
Type of method:
capillary viscometer (static)
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
98.2

Test 1

Capillary tube: IIc

Correction factor: 0.3049

Measured time [s]

Mean value [s]

316

316

316

316

316

316

 

Calculation

Viscosity [mm2/s]

time (mean value) x correction factor = viscosity

96.3484

 

Test 2

Capillary tube: IIa

Correction factor: 0.5212

Measured time [s]

Mean value [s]

192

192

192

192

192

192

 

Calculation

Viscosity [mm2/s]

time (mean value) x correction factor = viscosity

100.0704

 

Viscosity at 20 °C [mm2/s]

98.2

Conclusions:
A viscosity value of 98.2 mm2/s at 20°C was determined for the substance in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.

Description of key information

Viscosity: 98.2 mm2/s at 20°C (DIN 51562)

Key value for chemical safety assessment

Viscosity:
98.2 mm²/s (static)
at the temperature of:
20 °C

Additional information

A kinematic viscosity value of 98.2 mm2/s at 20°C was determined for the submission substance in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.