Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions (e.g. non-GLP)

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2010
Report Date:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: DIN-EN 13016-2
GLP compliance:
no
Type of method:
static method
Remarks:
MiniVap (Fa. Grabner-Instruments)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Analytical purity (GC): 99,23 % [m/m]
- Purity test date: 2009-01-21
- Source: MV 1049
- Sampling date: 2006-03-24
- Lot/LIMS-ID: 20091120085736

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
ca. 2 hPa
Remarks on result:
other: extrapolated result based on experimental result

Applicant's summary and conclusion

Conclusions:
Vapour pressure ca. 2 hPa at 20°C
Executive summary:

Vapour pressure ca.2 hPa at 20°C (extrapolated value)

All study results reported here were obtained using valid test methods and calibrated instruments. Standard operation procedures comply with the company’s Quality Management System certified by Deloitte Cert Umweltgutachter GmbH (Registration Numbers Z1 056-0308 and Z1 057 -0308, last certified March 2009)