Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

Adsorption

The adsorption coefficient Koc in soil and in sewage sludge of test chemical Reaction mass of 3H-Indolium, 2-[[2-(4-methoxyphenyl)-2-methylhydrazinylidene]methyl]-1,3,3-trimethyl- & acetate was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals (Experimental report, 2018). The solutions of the test substance and reference substances were prepared in appropriate solvents. A test item solution was prepared by accurately pipetting 4 microliter of test item and diluted with Acetonitrile up to 10 ml. Thus, the test solution concentration was 440 mg/l. The pH of test substance was 7.8. Each of the reference substance and test substance were analysed by HPLC at 210 nm. After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k(Annex - 2).The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor. The reference substances were chosen according to estimated Koc range of the test substance and generalized calibration graph was prepared. The reference substances were Acetanilide, 4-chloroaniline, 4-methylaniline(p-Tolouidine), N-methylaniline, p-toluamide, Aniline, 2,5 -Dichloroaniline, 4-nitrophenol, 2 - nitrophenol, 2 -nitrobenzamide, 3-nitrobenzamide, Nitrobenzene, 4-Nitrobenzamide, 1-naphtol, Direct Red 81, Benzoic acid methylester, Carbendazim, Benzoic acid phenylester, Xylene, Ethylbenzene, Toluene, Naphthalene, 1,2,3 -trichlorobenzene, Pentachlorophenol, 3,5-dinitrobenzamide, Benzamide, phenanthrene having Koc value ranging from 1.25 to 4.09. The Log Koc value of test chemical Reaction mass of 3H-Indolium, 2 -[[2 -(4 -methoxyphenyl)-2 -methylhydrazinyli dene]methyl]-1,3,3 -trimethyl- & acetate was determined to be 1.281± 0.013 at 25°C. This log Koc value indicates that the substance Reaction mass of 3H-Indolium, 2 -[[2 -(4 -methoxyphenyl) -2 -methylhydrazinylidene]methyl]-1,3,3-trimethyl- & acetate has a negligible sorption to soil and sediment and therefore have rapid migration potential to ground water.

Additional information

Adsorption

The adsorption coefficient Koc in soil and in sewage sludge of test chemical Reaction mass of 3H-Indolium, 2-[[2-(4-methoxyphenyl)-2-methylhydrazinylidene]methyl]-1,3,3-trimethyl- & acetate was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals (Experimental report, 2018). The solutions of the test substance and reference substances were prepared in appropriate solvents. A test item solution was prepared by accurately pipetting 4 microliter of test item and diluted with Acetonitrile up to 10 ml. Thus, the test solution concentration was 440 mg/l. The pH of test substance was 7.8. Each of the reference substance and test substance were analysed by HPLC at 210 nm. After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k(Annex - 2).The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor. The reference substances were chosen according to estimated Koc range of the test substance and generalized calibration graph was prepared. The reference substances were Acetanilide, 4-chloroaniline, 4-methylaniline(p-Tolouidine), N-methylaniline, p-toluamide, Aniline, 2,5 -Dichloroaniline, 4-nitrophenol, 2 - nitrophenol, 2 -nitrobenzamide, 3-nitrobenzamide, Nitrobenzene, 4-Nitrobenzamide, 1-naphtol, Direct Red 81, Benzoic acid methylester, Carbendazim, Benzoic acid phenylester, Xylene, Ethylbenzene, Toluene, Naphthalene, 1,2,3 -trichlorobenzene, Pentachlorophenol, 3,5-dinitrobenzamide, Benzamide, phenanthrene having Koc value ranging from 1.25 to 4.09. The Log Koc value of test chemical Reaction mass of 3H-Indolium, 2 -[[2 -(4 -methoxyphenyl)-2 -methylhydrazinyli dene]methyl]-1,3,3 -trimethyl- & acetate was determined to be 1.281± 0.013 at 25°C. This log Koc value indicates that the substance Reaction mass of 3H-Indolium, 2 -[[2 -(4 -methoxyphenyl) -2 -methylhydrazinylidene]methyl]-1,3,3-trimethyl- & acetate has a negligible sorption to soil and sediment and therefore have rapid migration potential to ground water.