Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 June 2017 to 06 July 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
EU Regulation 440/2008

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Constituent 1
Chemical structure
Reference substance name:
N,N,N-trimethyl-3-nitroanilinium chloride
EC Number:
252-279-5
EC Name:
N,N,N-trimethyl-3-nitroanilinium chloride
Cas Number:
34907-26-1
Molecular formula:
C9H13N2O2.Cl
IUPAC Name:
N,N,N-trimethyl-3-nitroanilinium chloride
Test material form:
solid
Details on test material:
Fine powder used for physical chemistry testing
Specific details on test material used for the study:
Note in the report: N,N,N-trimethyl-nitroanilinium chloride sample is refered to as "EGB11-5-1 NITRI"

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
4 min
Moisture (wt %):
0
Remarks on result:
other: Burned for 160mm for 4 mins, not highly flammable, no further testing required.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Burned for 160mm for 4 mins, not highly flammable, no further testing required.
Executive summary:

Burned for 160mm for 4 mins, not highly flammable, no further testing required.