Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.4 (Test method for self-heating substances)
GLP compliance:
yes (incl. QA statement)

Test material

1
Chemical structure
Reference substance name:
[29H,31H-phthalocyaninato-N29,N30,N31,N32]cobalt
EC Number:
222-012-7
EC Name:
[29H,31H-phthalocyaninato-N29,N30,N31,N32]cobalt
Cas Number:
3317-67-7
Molecular formula:
C32H16N8Co
IUPAC Name:
[29H,31H-phthalocyaninato-N29,N30,N31,N32]cobalt

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: UN test N.1: The test item became hard and glowed. A combustion was observed over 4/5 cm in 20 minutes.

Any other information on results incl. tables

Self-heating substances / mixtures

Test procedure

100 mm sample cube at 140°C

Result

negative outcome (no effect observed) UN test N.4 : No self-ignition of the test item was recorded and the temperature of the sample did not exceed the oven temperature by 60 °C.

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
UN test N.1: Based on partial and slow combustion, the test item was not classified as a flammable solid of UN Division 4.1 and not classified according to EC No. 1272/2008 (CLP).
UN test N.4: No self-ignition of the test item was recorded and the temperature of the sample did not exceed the oven temperature by 60 °C. Not classified in UN Division 4.2 and not classified according to EC No. 1272/2008 (CLP).