Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 feb to 6 march 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: Normalab NPV 310 - This apparatus is in compliance with the following standard: ISO Standard 3679 (September 2004)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Specific details on test material used for the study:
batch number 5087 - production date : 2018 january

Results and discussion

Flash point
Key result
Flash point:
62 °C
Atm. press.:
97.3 kPa

Applicant's summary and conclusion

Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The flash point of the test item was 62.0 °C ± 0.5 °C (corrected value). Hence, the substance is not classified as a flammable liquid according to CLP criteria of Regulation (EC) N°1272/2008.
The substance is classified as Flammable Liquid Category 4 according to GHS criteria of UN Globally Harmonized System.