Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 305-105-8 | CAS number: 94334-32-4 Extractives and their physically modified derivatives such as tinctures, concretes, absolutes, essential oils, oleoresins, terpenes, terpene-free fractions, distillates, residues, etc., obtained from Thuya plicata, Cupressaceae.
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Guidance on Safe Use
Administrative data
First-aid measures
Do not leave affected person unattended. Remove victim out of the danger area. Keep affected person warm, still and covered. Take off immediately all contaminated clothing. In all cases of doubt, or when symptoms persist, seek medical advice. In case of unconsciousness place person in the recovery position. Never give anything by mouth.
Following inhalation : If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. In case of respiratory tract irritation, consult a physician. Provide fresh air.
Following skin contact : Wash with plenty of soap and water.
Following eye contact : Remove contact lenses, if present and easy to do. Continue rinsing. Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart.
Following ingestion : Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting.
Symptoms and effects are not known to date.
Indication of any immediate medical attention and special treatment needed : none.
Fire-fighting measures
Suitable extinguishing media : water spray, alcohol resistant foam.
Unsuitable extinguishing media :water jet
Special hazards arising from the substance or mixture : In case of insufficient ventilation and/or in use, may form flammable/explosive vapour-air mixture. Solvent vapours are heavier than air and may spread along floors. Places which are not ventilated, e.g. unventilated below ground level areas such as trenches, conduits and shafts, are particularly prone to the presence of flammable substances or mixtures.
Hazardous combustion products : nitrogen oxides (NOx), carbon monoxide (CO), carbon dioxide (CO2)
Advice for firefighters : In case of fire and/or explosion do not breathe fumes. Co-ordinate firefighting measures to the fire surroundings. Do not allow firefighting water to enter drains or water courses. Collect contaminated firefighting water
separately. Fight fire with normal precautions from a reasonable distance.
Accidental release measures
For non-emergency personnel : Remove persons to safety.
For emergency responders : Wear breathing apparatus if exposed to vapours/dust/spray/gases.
Environmental precautions : Keep away from drains, surface and ground water. Retain contaminated washing water and dispose it.
Advices on how to contain a spill : Covering of drains.
Advices on how to clean up a spill : Wipe up with absorbent material (e.g. cloth, fleece). Collect spillage (sawdust, kieselgur (diatomite), sand, universal binder).
Appropriate containment techniques : Use of adsorbent materials.
Other information relating to spills and releases : Place in appropriate containers for disposal. Ventilate affected area.
Handling and storage
Measures to prevent fire as well as aerosol and dust generation : Use local and general ventilation. Avoidance of ignition sources. Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge. Use only in well-ventilated areas. Due to danger of explosion, prevent leakage of vapours into cellars, flues and ditches. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting equipment. Use only non-sparking tools
Warning : Places which are not ventilated, e.g. unventilated below ground level areas such as trenches, conduits and shafts, are particularly prone to the presence of flammable substances or mixtures. Vapours are heavier than air, spread along floors and form explosive mixtures with air. Vapours may form explosive mixtures with air.
Advice on general occupational hygiene : Wash hands after use. Do not to eat, drink and smoke in work areas. Remove contaminated clothing and protective equipment before entering eating areas. Never keep food or drink in the vicinity of chemicals. Never place chemicals in containers that are normally used for food or drink. Keep away from food, drink and animal feedingstuffs.
Explosive atmospheres : Keep container tightly closed and in a well-ventilated place. Use local and general ventilation. Keep cool.Protect from sunlight.
Flammability hazards : Keep away from sources of ignition - No smoking. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharge. Protect from sunlight.
Incompatible substances or mixtures : Observe hints for combined storage.
Ventilation requirements : Use local and general ventilation. Ground/bond container and receiving equipment.
Packaging compatibilities : Only packagings which are approved (e.g. acc. to ADR) may be used.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- 1992
Shipping information
- Proper shipping name and description:
- Flammable liquid, toxic, n.o.s.
- Chemical name:
- Thuyone, pinene
- Language:
- English
- Labels:
- 3 + 6.1 + "fish and tree"
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- 1992
Shipping information
- Proper shipping name and description:
- Flammable liquid, toxic, n.o.s.
- Chemical name:
- thuyone, pinene
- Language:
- English
- Labels:
- 3 + 6.1 + "fish and tree"
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- 1992
Shipping information
- Proper shipping name and description:
- Flammable liquid, toxic, n.o.s.
- Chemical name:
- thuyone, pinene
- Labels:
- 3 + 6.1 + "fish and tree"
Special provisions / remarks
- Remarks:
- Marine pollutant = true
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- 1992
Shipping information
- Proper shipping name and description:
- Flammable liquid, toxic, n.o.s.
- Chemical name:
- thuyone, pinene
- Labels:
- 3 + 6.1 + "fish and tree"
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
General ventilation.
Wear eye/face protection.
Hand protection : Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leak-tightness/impermeability prior to use. In the case of wanting to use the gloves again, clean them before taking off and air them well. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.
Other protection measures : Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended. Wash hands thoroughly after handling.
Respiratory protection : In case of inadequate ventilation wear respiratory protection.
Environnemental exposure controls : Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Stability and reactivity
Reactivity : risk of ignition if heated
Conditions to avoid : Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Possibility of hazardous reaction : No known hazardous reactions.
Incompatible materials : not known
Disposal considerations
Waste treatment-relevant information : Solvent reclamation/regeneration.
Sewage disposal-relevant information : Do not empty into drains. Avoid release to the environment. Refer to special instructions/safety data sheets.
Waste treatment of containers/packagings : It is a dangerous waste; only packagings which are approved (e.g. acc. to ADR) may be used. Completely emptied packages can be recycled. Handle contaminated packages in the same way as the substance itself.
Properties of waste which render it hazardous : flammable, toxic for health, toxic for environnement
Remarks : Please consider the relevant national or regional provisions. Waste shall be separated into the categories that can be handled separately by the local or national waste management facilities.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.