Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
3 dec 2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
GLP compliance:
no
Other quality assurance:
other: ISO 9001
Type of method:
equilibrium method closed cup
Specific details on test material used for the study:
batch 2319
Key result
Flash point:
57 °C
Atm. press.:
1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
With a flash point at 57°C, the thuya plicata essential oil is classified as a flammable liquid category 3.
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
3 dec 2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
GLP compliance:
no
Other quality assurance:
other: ISO 9001
Type of method:
equilibrium method closed cup
Specific details on test material used for the study:
batch 24/11
Key result
Flash point:
58 °C
Atm. press.:
1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
With a flash point at 58°C, the thuya plicata essential oil is classified as a flammable liquid category 3.
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 jan 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 1523 (Determination of flash point - Closed cup equilibrium method)
GLP compliance:
no
Other quality assurance:
other: ISO 9001
Type of method:
equilibrium method closed cup
Specific details on test material used for the study:
batch 4984
Key result
Flash point:
56 °C
Atm. press.:
1 atm
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
With a flash point at 56°C, the thuya plicata essential oil is classified as a flammable liquid category 3.

Description of key information

Three tests have been made and showed the following results :

 test #  result of flash point (°C)  method  batch year of the test 
 test 1  57  ISO 1523  2319  2010
 test 2  58  ISO 1523  24/11  2010
 test 3  56  ISO 1523  4984  2018

Key value for chemical safety assessment

Flash point at 101 325 Pa:
56 °C

Additional information

The flash point of test item is comprised between 56°C and 58°C,, with a mean value at 57°C, so the essential is classified as a flammable liquid category 3.