Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12.02.2018 to 21.02.2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
2006
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
2008
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7950 (Vapor Pressure)
Version / remarks:
1996
GLP compliance:
yes (incl. QA statement)
Remarks:
consilab, Gesellschaft für Anlagensicherheit mbH, Industriepark Höchst, G830/G840, 65926 Frankfurt am Main (Germany)
Type of method:
effusion method: Knudsen cell

Test material

Constituent 1
Reference substance name:
L-Threonine, N-coco acyl derivs., monosodium salts
Cas Number:
90583-79-2
Molecular formula:
n/a
IUPAC Name:
L-Threonine, N-coco acyl derivs., monosodium salts
Test material form:
solid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1, Kyobashi 1-chome, Chuo-ku, Tokyo 104-8315, Japan, Batch No.: 160329
- Expiration date of the lot/batch: 2019-03-29
- Purity test date: 2016-06-09

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: stored at ambient temperature

Results and discussion

Vapour pressureopen allclose all
Key result
Temp.:
20 °C
Vapour pressure:
< 0.059 Pa
Key result
Temp.:
25 °C
Vapour pressure:
< 0.059 Pa
Key result
Temp.:
50 °C
Vapour pressure:
< 0.059 Pa

Applicant's summary and conclusion

Conclusions:
The test item showed no evaluable vapour pressure curve in the temperature range of 71 to 101°C and 121 to 151°C, respectively. Therefore the vapour pressures for the temperatures 20, 25, and 50°C were estimated to be <5.9 x 10E-2 Pa each based on the maximum vapour pressure measured.
Executive summary:

The vapour pressure of the test item was investigated in a study conducted according to OECD Guideline 104 (Vapour Pressure Curve; 2006), EU Method A.4 (Vapour Pressure; 2008), and EPA OPPTS 830.7950 (Vapor Pressure; 1996) using the effusion method (Knudsen cell). The test item showed no evaluable vapour pressure curve in the temperature range of 71 to 101°C and 121 to 151°C, respectively. Therefore the vapour pressures for the temperatures 20, 25, and 50°C were estimated to be <5.9 x 10E-2 Pa each based on the maximum vapour pressure measured.