Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-02-24 to 2010-02-24
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study completed according to test method A.17 'Oxidising Properties (Solids)' as described in Directive 92/69/EEC.
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
GLP compliance:
yes (incl. QA statement)
Remarks:
Included in study report
Contact with:
powdered cellulose
Key result
Sample tested:
test mixture (not specified)
Parameter:
burning rate
Remarks on result:
other: It is difficult to ignite the test item. After removing the heated platinum wire the flame disappeared immediately.
Interpretation of results:
GHS criteria not met
Conclusions:
The test item N,N-Bis(2-hydroxyethyl)-p-phenylenediamine sulphate monohydrate has no oxidising properties according to the definition in Directive 92/69/EEC, method A.17.
Executive summary:

The oxidising properties (solids) were determined according to the test method A.17 'Oxidising Properties (Solids)' as described in Directive 92/69/EEC. The test item N,N-Bis(2-hydroxyethyl)-p-phenylenediamine sulphate monohydrate has no oxidising properties according to the definition in Directive 92/69/EEC, method A.17.

Description of key information

The test item N,N-Bis(2-hydroxyethyl)-p-phenylenediamine sulphate monohydrate has no oxidising properties according to the definition in Directive 92/69/EEC, method A.17.

Key value for chemical safety assessment

Oxidising properties:
non oxidising

Additional information

Justification for classification or non-classification