Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 March 2017 to 28 March 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
0 s
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The substance is non-flammable
Executive summary:

In the preliminary test according to EU A.10 the substance pile failed to ignite during the 2 minutes that the Bunsen flame was applied. The substance is considered non-flammable.

Description of key information

In the preliminary test according to EU A.10 the substance pile failed to ignite during the 2 minutes that the Bunsen flame was applied.

During handling and use it was deduced that the substance is not flammable in contact with water and is not pyrophoric. Therefore the substance is considered non-flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Based on the outcome of the tests and experience when handling the substance, no classification according to Regulation (EC) No 1907/2006