Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 December 2017 to 14 December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N
Key result
Parameter:
thermal sensitivity - Koenen test: limiting diameter (mm)
Remarks on result:
not thermal sensitive if heated under defined confinement

- BAM Fallhammer

Mass (kg) Height (m) Energy (J) Test number

Comments

1 2 3 4 5 6  
10 0.4 40 X X X X X X No reaction observed

X: no reaction or decomposition

The sample of test material was observed to exhibit no reaction at 40J. The test result is considered Negative (-) (according to the EC Classification, Packaging & Labelling of Dangerous Substances in the European Union Part 2, Testing Methods, Jan 97)

- BAM Friction

Mass (kg) Load (N) Test number

Comments

1 2 3 4 5 6
8.34 360 X X X X X X Decomposition

X: no reaction or decomposition

The sample of test material was observed to discolour to brown/black but no explosion was exhibited at 360N. The test result is considered Negative (-) (according to the EC Classification, Packaging & Labelling of Dangerous Substances in the European Union Part 2, Testing Methods, Jan 97)

- Koenen Tube

Mass of sample (g) Orifice diameter (mm) Time to first ignition Expolsion
12.9 6 37 X
12.9 6 32 X
12.9 6 33 X
12.9 2 41 X
12.9 2 37 X
12.9 2 40 X

X: fewer than 3 fragments

The sample did not exhibit an explosion during any of the tests. The test result is therefore considered negative.

Interpretation of results:
other: Not explosive in accordance with EU criteria
Conclusions:
Under the conditions of the study, the test material was determined to be non-explosive.
Executive summary:

The explosive properties of the test material was investigated in a GLP study which was conducted in accordance with the standardised guideline EU Method A.14.

Under the conditions of this study, the test material was considered to be non explosive.

Description of key information

Under the conditions of the study, the test material was determined to be non-explosive.

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

The explosive properties of the test material was investigated in a GLP study which was conducted in accordance with the standardised guideline EU Method A.14.

Under the conditions of this study, the test material was considered to be non explosive.

Justification for classification or non-classification

In accordance with the criteria for classification as defined in Annex I, Regulation (EC) No 1272/2008, the substance does not require classification with respect to explosivity.