Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
other: data from collection of data
Adequacy of study:
other information
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data

Data source

Reference
Reference Type:
review article or handbook
Title:
GESTIS-Stoffdatenbank
Author:
Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung
Bibliographic source:
http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index.jsp

Materials and methods

Test material

Reference
Name:
Unnamed
Test material form:
liquid

Results and discussion

Vapour pressureopen allclose all
Key result
Temp.:
20 °C
Vapour pressure:
173 hPa
Key result
Temp.:
30 °C
Vapour pressure:
268 hPa
Key result
Temp.:
40 °C
Vapour pressure:
402 hPa
Key result
Temp.:
50 °C
Vapour pressure:
586 hPa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of tetrahydrofuran is 173, 268, 402 and 586 hPa at 20, 30, 40 and 50 °C, respectively.